GAS ANALYSIS INSTRUMENTS

Gas Analyzers for different applications :

Flue Gas Analyzer : Boiler, Furnace, Cement, Kiln exhaust emission gas monitoring, continuous emission monitoring for
    environmental protection. Flue gas analyzers available in advanced high performance NDIR (Infrared) as well as economical
    ECD (Electrochemical) Technology.
Infrared Coal Gas Analyzer : Coal Chemical process, sponge iron and steel, ferro alloys smelting process, heat treatment, gas furnace.
Infrared Bio Gas Analyzer : Bio Gas plant, Waste water treatment plant, sludge digestion, land fill sites. Flue, Coal & Bio Gas Analyzers are
    available in online and portable types.
Infrared Combustion Efficiency Analyzer : Boiler, Furnace, exhaust emission gas and combustion efficiency control.
Automobile Emission Gas Analyzer : Auto Emission checking stations, automobile service centers and vehicle pollution monitoring units.
Opacity Meter for Diesel Engine : Diesel Engine manufacturers, pollution monitoring stations.
Infrared Gas Analyzer (ppm range) : Air monitoring in chemical, fertilizer plants for refined gas monitoring,
    air separation applications, research  and educational institutes.
Single Gas Analyzers : CO, CO2, CH4, CxHy, SO2, NO2, H2s
Oxygen Gas Analyzers : ECD / Paramagnetic / Zirconia
Hydrogen Gas Analyzers : ECD
Gas Leakage Transmitters : CO,CO2, CH4, H2S
Handheld Gas Leakage Detectors : CO,CO2, CH4, H2S

Accessores : Gas Conditioning Systems with Nox Converter, Conditioning device to remove dust, water and oil, heated sampling probe,
    heated line, sampling pump, 4~20 mA output, Alarm with relay output at pre-settable gas concentration levels, Gas temperature, pressure and
    flow measurements, BTU Index (Gas calorific value) calculations, data logging upto 1500 sets of 7 data.
 
 

  FUEL GAS ANALYSER Manufacturer Supplier and Exporters

 

Applications :
Monitoring of boiler and furnace exhaust emission gas and combustion efficiency used for
continuous emission monitoring system (CEMS) in cement production line.

Specifications

 
Measuring Gas Technology Range Resolution Accuracy
SO2   NDIR 0-2000ppm 1 ppm +1%
NO   NDIR 0-2000ppm 1 ppm  +1%
CO   NDIR  0-5000ppm 1 ppm +1%
CO2 NDIR  0-25%  0.01% +2%
O2    ECD 0-25% 0.01% +3%
NOx (Optional) Catalytic Gas
Conversion
0-5000ppm 1 ppm +2%
Measurement range can be customised based on the requirements.
 

DOWNLOAD CATALOGUE

 

DOWNLOAD MANUAL


Highslide JS
 
 

Click On Image For ZOOM

 

  COAL GAS ANALYZER

 
Applications :

Coal chemical process, Steel production process in blast furnace, convertor, coking, iron ore smelting reduction process, Coal or biomass gasification process.

Specifications
 
  Measurement Gases :
 & (Technology)
 
  CO, CO2, CH4, CxHy (NDIR)
  H2 (TCD)
  O2 (ECD)
  Measuring Range :   CO: 0~100%, CO2: 0~50%, CH4: 0~10%
  H2: 0~50%, O2: 0~25%, CxHy: 0~5% Measurement    
  range can be customized based on the requirement.
  Resolution   0.01%
  Accuracy   CO, CO2, CH4, CxHy: +2%FS
  H2, O2: +3% FS
 

DOWNLOAD CATALOGUE

 

DOWNLOAD MANUAL

 

 
Highslide JS
 
 

Click On Image For ZOOM

 

  BIO GAS ANALYZER

 

Applications :

Biogas plants, Anaerobic digestion, sewage treatment plants, sludge digestion, bio methane production plants, landfill sites, etc.

Specifications
 
  Measurement Gases :
  & (Technology)
 
  CO2, CH4 (NDIR)
  H2S, O2 (ECD)
  Measuring Range :   CO2: 0~100%, CH4: 0~100%,
  H2S: 0~9999ppm, O2: 0~25%
  Measurement range can be customized
  based on the requirement.
  Resolution :   CO2, CH4, O2: 0.01%, H2S: 1ppm
  Accuracy :   CH4, CO2: + 2%FS
  O2, H2S: +3%FS
 
 

DOWNLOAD CATALOGUE

 

DOWNLOAD MANUAL


 
Highslide JS
 
 

Click On Image For ZOOM

 

  AUTOMOBILE EMISSION GAS ANALYZER

 

Applications :

Automobile Industry to check the emission in automobiles, emission checking stations, automobile service centres & vehicle pollution monitoring units, etc.

Specifications
 
  Measurement Gases :
  & (Technology)
 
  CO, CO2, HC (NDIR),
  O2 & NO (ECD)
  Measuring Range :   CO : 0~10%, CO2 : 0~20%,
  O2 : 0~25%, HC : 0~9999ppm
  NO : 0~5000ppm (optional)
  Resolution :   CO, CO2, O2 :0.01%,
  HC & NO : 1ppm
  Accuracy :   CO: +0.06%, CO2 : +0.5%,
  O2 : +0.5%, HC: +12ppm,
  NO+25 ppm
 
Features

* Compact, portable, ergonomic design.
*  Unique infrared NDIR gas sensor for CO, CO2, HC and electrochemical
    (ECD) sensor for O2 & NO.
*  Can measure concentration of CO, CO2, HC, O2 & NO (optional) simultaneously.

 
 

DOWNLOAD CATALOGUE

 

DOWNLOAD MANUAL


 
Highslide JS
 
 

Click On Image For ZOOM

 

  GAS DETECTOR HAND HELD

 

Applications :

Chemical industries, oil & gas storage and transportation, mining, metallurgy, LPG stations, spray painting, leakage of natural gas, etc.

Specifications
 
  Measurement Gases :
  & (Technology
  NDIR for CH4/CO2 &
  ECD for CO/H2S
  Measuring Range :    0~10% vol
  10~100% vol
  Resolution :    0.01% in the range of 0~10% vol
   0.1% in the range of 10~100% vol
  Accuracy :   +1% FS
  Response time :   25 secs at 250C

Features

*  High Precision and Reliable NDIR principle for CH4/CO2 & ECD principle for CO/H2S
*  Preliferation sampling method
*  Display of gas concentration value.
 
 

DOWNLOAD CATALOGUE

 

DOWNLOAD MANUAL


 
Highslide JS
 
 

Click On Image For ZOOM

 

  LEAKAGE GAS TRANSMITTER

 

Applications :

Gas transmitters are widely used for the continuous monitoring of gas concentration in petrochemical process industries, mining and metallurgy, leakage of natural gas, petrol and
gas storage, transportation and distribution, power generation, marine and cargo handling
and oil rigs, etc.

Specifications
 
  Measurement Gases :
  & (Technology)
  NDIR for CH4/CO2 &
  ECD for CO/H2S
  Power Supply :   8~25 V DC
  Measuring Range :   0~5% vol
  5~100% vol
  Resolution :   0.01% in the range of 0~5% vol
  0.1% in the range of 5~100% vol
  Accuracy :   +1% FS
  Response time :   C25 secs at 250C

Features

*  High Precision and Reliable NDIR principle for CH4/CO2 & ECD principle for CO/H2S
*  Preliferation sampling method
*  Display of gas concentration value
 

 

DOWNLOAD CATALOGUE

 

DOWNLOAD MANUAL


 

Our Product Range :

 


|   HOME  |    PROFILE   |   PRODUCTS  |   RESOURCES   |   CONTACT  |    DOWNLOAD BROCHURE  |   SITEMAP   |   TOP   |

BEST VIEW : 1024 X 768 Pixels   Contech Instruments Ltd. all rights reserved